1.Reason: The hydraulic oil temperature is too high .
solution: check the hydraulic oil cooling system to ensure its normal operation.
2.Reason: Serious leakage in the system, resulting in continuous work of the pump.
Solution: Check the leakage problem in the system and repair the leakage site.
3.Cause: hydraulic oil pollution or deterioration .
solution: replace the deteriorated or contaminated hydraulic oil.
4.Reason: the design of the hydraulic system is unreasonable, resulting in a long-term high load state of the pump.
Solution: Optimize the design of the hydraulic system to avoid long-term high load of the pump.